Executive Summary
Introduction
Health Issues
Environmental Assessment
Mold Remediation
Hazard Communication
Conclusion
Notes and References
Important Links
Download Guidelines
 
2012 updated Mold remediation guidelines

 

 

 

Notes and References

1. Bata A, Harrach B, Kalman U, Kis-tamas A, Lasztity R. Macrocyclic Trichothecene Toxins Produced by Stachybotrys atra Strains Isolated in Middle Europe. Applied and Environmental Microbiology 1985; 49:678-81.

2. Jarvis B, "Mycotoxins and Indoor Air Quality," Biological Contaminants in Indoor Environments, ASTM STP 1071, Morey P, Feely Sr. J, Otten J, Editors, American Society for Testing and Materials, Philadelphia, 1990.

3. Yang C, Johanning E, "Airborne Fungi and Mycotoxins," Manual of Environmental Microbiology, Hurst C, Editor in Chief, ASM Press, Washington, D.C., 1996

4. Jarvis B, Mazzola E. Macrocyclic and Other Novel Trichothecenes: Their Structure, Synthesis, and Biological Significance. Acc. Chem. Res. 1982; 15:388-95.

5. Von Essen S, Robbins R, Thompson A, Rennard S. Organic Dust Toxic Syndrome: An Acute Febrile Reaction to Organic Dust Exposure Distinct from Hypersensitivity Pneumonitis. Clinical Toxicology 1990; 28(4):389-420.

6. Richerson H. Unifying Concepts Underlying the Effects of Organic Dust Exposures. American Journal of Industrial Medicine 1990; 17:139-42.

7. Malmberg P, Rask-Andersen A, Lundholm M, Palmgren U. Can Spores from Molds and Actinomycetes Cause an Organic Dust Toxic Syndrome Reaction?. American Journal of Industrial Medicine 1990; 17:109-10.

8. Malmberg P. Health Effects of Organic Dust Exposure in Dairy Farmers. American Journal of Industrial Medicine 1990; 17:7-15.

9. Yoshida K, Masayuki A, Shukuro A. Acute Pulmonary Edema in a Storehouse of Moldy Oranges: A Severe Case of the Organic Dust Toxic Syndrome. Archives of Environmental Health 1989; 44(6): 382-84.

10. Lecours R, Laviolette M, Cormier Y. Bronchoalveolar Lavage in Pulmonary Mycotoxicosis. Thorax 1986; 41:924-6.

11. Levetin E. "Fungi," Bioaerosols, Burge H, Editor, CRC Press, Boca Raton, Florida, 1995.

12. Husman T. Health Effects of Indoor-air Microorganisms. Scand J Work Environ Health 1996; 22:5-13.

13. Miller J D. Fungi and Mycotoxins in Grain: Implications for Stored Product Research. J Stored Prod Res 1995; 31(1):1-16.

14. Cookingham C, Solomon W. "Bioaerosol-Induced Hypersensitivity Diseases," Bioaerosols, Burge H, Editor, CRC Press, Boca Raton, Florida, 1995.

15. Rautiala S, Reponen T, Nevalainen A, Husman T, Kalliokoski P. Control of Exposure to Airborne Viable Microorganisms During Remediation of Moldy Buildings; Report of Three Case Studies. American Industrial Hygiene Association Journal 1998; 59:455-60.

16. Dales R, Zwanenburg H, Burnett R, Franklin C. Respiratory Health Effects of Home Dampness and Molds among Canadian Children. American Journal of Epidemiology 1991; 134(2): 196-203.

17. Hodgson M, Morey P, Leung W, Morrow L, Miller J D, Jarvis B, Robbins H, Halsey J, Storey E. Building-Associated Pulmonary Disease from Exposure to Stachybotrys chartarum and Aspergillus versicolor. Journal of Occupational and Environmental Medicine 1998; 40(3)241-9.

18. Croft W, Jarvis B, Yatawara C. Airborne Outbreak of Trichothecene Toxicosis. Atmospheric Environment 1986; 20(3)549-52.

19. DeKoster J, Thorne P. Bioaerosol Concentrations in Noncomplaint, Complaint, and Intervention Homes in the Midwest. American Industrial Hygiene Association Journal 1995; 56:573-80.

20. Johanning E, Biagini R, Hull D, Morey P, Jarvis B, Landbergis P. Health and Immunological Study Following Exposure to Toxigenic Fungi (Stachybotrys chartarum) in a Water-Damaged Office Environment. Int Arch Occup Environ Health 1996; 68:207-18.

21. Montana E, Etzel R, Allan T, Horgan T, Dearborn D. Environmental Risk Factor Associated with Pediatric Idiopathic Pulmonary Hemorrhage and Hemosiderosis in a Cleveland Community. Pediatrics 1997; 99(1)

22. Etzel R, Montana E, Sorenson W G, Kullman G, Allan T, Dearborn D. Acute Pulmonary Hemorrhage in Infants Associated with Exposure to Stachybotrys atra and Other Fungi. Ach Pediatr Adolesc Med 1998; 152:757-62.

23. CDC. Update: Pulmonary Hemorrhage/Hemosiderosis Among Infants --- Cleveland, Ohio, 1993 - 1996. MMWR 2000; 49(9): 180-4.

24. Burge H, Otten J. "Fungi," Bioaerosols Assessment and Control, Macher J, Editor, American Conference of Industrial Hygienists, Cincinnati, Ohio, 1999.

25. do Pico G. Hazardous Exposure and Lung Disease Among Farm Workers. Clinics in Chest Medicine 1992; 13(2):311-28.

26. Hodgson M, Morey P, Attfield M, Sorenson W, Fink J, Rhodes W, Visvesvara G. Pulmonary Disease Associated with Cafeteria Flooding. Archives of Environmental Health 1985; 40(2):96-101.

27. Weltermann B, Hodgson M, Storey E, DeGraff, Jr. A, Bracker A, Groseclose S, Cole S, Cartter M, Phillips D. Hypersensitivity Pneumonitis: A Sentinel Event Investigation in a Wet Building. American Journal of Industrial Medicine 1998; 34:499-505.

28. Band J. "Histoplasmosis," Occupational Respiratory Diseases, Merchant J, Editor, U.S. Department of Health and Human Services, Washington D.C., 1986.

29. Bertolini R. "Histoplasmosis A Summary of the Occupational Health Concern," Canadian Centre for Occupational Health and Safety. Hamilton, Ontario, Canada, 1988.

30. Yang C. P&K Microbiology Services, Inc. Microscopic Examination of Sticky Tape or Bulk Samples for the Evaluation and Identification of Fungi. Cherry Hill, New Jersey.

31. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Thermal Environmental Conditions for Human Occupancy - ASHRAE Standard (ANSI/ASHRAE 55-1992). Atlanta, Georgia, 1992.

 

  

Mold Busters  |  Air Quality Test in Ottawa  |  Air Quality Testing in Montreal  |  Mould Inspection in Ottawa  |  Infrared Test in Ottawa

 

Mold Busters Copyright 2005-2012 Mold (mould) Removal and Remediation Services.